中文字字幕一区二区三区四区五区,裸体照片一区二区三区,日a韩国产在线,综合五月久久

  • 
    
      1. <pre id="4uudo"><label id="4uudo"><th id="4uudo"></th></label></pre>
        您好,歡迎進(jìn)入研域(上海)化學(xué)試劑有限公司網(wǎng)站!
        一鍵分享網(wǎng)站到:
        • 技術(shù)文章ARTICLE

          您當(dāng)前的位置:首頁(yè) > 技術(shù)文章 > 心肌營(yíng)養(yǎng)素1(CT1)ELISA試劑盒英文說(shuō)明書

          心肌營(yíng)養(yǎng)素1(CT1)ELISA試劑盒英文說(shuō)明書

          發(fā)布時(shí)間: 2017-05-21  點(diǎn)擊次數(shù): 1500次

          心肌營(yíng)養(yǎng)素1(CT1)ELISA試劑盒
          適用生物 Homo sapiens (Human,人)
          檢測(cè)范圍 15.63-1000pg/mL 靈敏度 5.5pg/mL
          樣本類型 Serum, plasma and other biological fluids.
          實(shí)驗(yàn)時(shí)長(zhǎng) 4.5h 實(shí)驗(yàn)方法 雙抗夾心法 

          心肌營(yíng)養(yǎng)素1(CT1)ELISA試劑盒    規(guī)格 96T
          ELISA Kit for Cardiotrophin 1 (CT1)
          FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!
          Organism species Homo sapiens (Human)
          Product No. SEA810Hu
          Sample type Serum, plasma and other biological fluids.

          心肌營(yíng)養(yǎng)素1(CT1)ELISA試劑盒    Format 96-well strip plate
          Assay length 4.5 hours
          Detection range 15.63-1000pg/mL The standard curve concentrations used for the ELISA’s were 1000pg/mL, 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL, 31.25pg/mL, 15.63pg/mL 
          Sensitivity The minimum detectable dose of this kit is typically less than 5.5pg/mL.
          Specificity
          This assay has high sensitivity and excellent specificity for detection of Cardiotrophin 1 (CT1).
          No significant cross-reactivity or interference between Cardiotrophin 1 (CT1) and analogues was observed. Recovery
          Matrices listed below were spiked with certain level of recombinant Cardiotrophin 1 (CT1) and the recovery rates were calculated by comparing the measured value to the expected amount of Cardiotrophin 1 (CT1) in samples.
          Matrix Recovery range (%) Average(%)
          serum(n=5) 82-103 101
          EDTA plasma(n=5) 95-102 99
          heparin plasma(n=5) 85-99 93
          Precision
          Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cardiotrophin 1 (CT1) were tested 20 times on one plate, respectively.
          Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cardiotrophin 1 (CT1) were tested on 3 different plates, 8 replicates in each plate.
          CV(%) = SD/meanX100
          Intra-Assay: CV<10%
          Inter-Assay: CV<12%

          心肌營(yíng)養(yǎng)素1(CT1)ELISA試劑盒     Linearity
          The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cardiotrophin 1 (CT1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
          Sample 1:2 1:4 1:8 1:16
          serum(n=5) 81-88% 81-92% 96-104% 78-104%
          EDTA plasma(n=5) 78-97% 93-105% 78-97% 84-92%
          heparin plasma(n=5) 94-105% 78-102% 88-102% 79-101%
          Stability
          The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
          To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. Reagents and materials provided
          Reagents Quantity Reagents Quantity
          Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
          Standard 2 Standard Diluent 1×20mL
          Detection Reagent A 1×120μL Assay Diluent A 1×12mL
          Detection Reagent B 1×120μL Assay Diluent B 1×12mL
          TMB Substrate 1×9mL Stop Solution 1×6mL
          Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1
          Assay procedure summary
          1. Prepare all reagents, samples and standards;
          2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;
          3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;
          4. Aspirate and wash 3 times;
          5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
          6. Aspirate and wash 5 times;
          7. Add 90μL Substrate Solution. Incubate 15-25 minutes at 37oC;
          8. Add 50μL Stop Solution. Read at 450nm immediay.

          心肌營(yíng)養(yǎng)素1(CT1)ELISA試劑盒    Test principle
          The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cardiotrophin 1 (CT1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Cardiotrophin 1 (CT1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cardiotrophin 1 (CT1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cardiotrophin 1 (CT1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

        產(chǎn)品中心 Products
        在線客服 聯(lián)系方式

        服務(wù)熱線

        021-54479081
        021-54461587

      2. 
        
          1. <pre id="4uudo"><label id="4uudo"><th id="4uudo"></th></label></pre>